Trio-Kenwood Communication, inc.
Service Bulletin no. 862 (14-4-1982)
When operated with a TS-130 series
transceiver, the dial lamp on the external VFO will remain on if the power
supply remains on, ever through the transceiver is off. Adding a transistor
switch on the VFO-120 switch unit X41-1240-00 will provide automatic lamp
operation from the transceiver power switch.
On the Switch unit, add transistor
Q1 2SC1959(Y) (V03-1959-06) as a pilot light ground switch, controlled by
the transceiver 9V DC line. Connect Q1 emitter to ground, collector to the
pilot light ground (either the lead, or connector CJ-2, pin 2) and base
through a 4.7 Kohm resistor (R9) (RD14CB2E472J) to the 9V line.
Note:
- This change may be applied to units before serial number
110001.
- Installation time for this procedure is ½ hour or less.